N gas equipment is connected to interior piping and properly vented.
Gas meter room requirements uk.
Meter compartment a room or cupboard specifically designed to house the meter installation n j u g national joint utilities group regulator a device whose function is to control pressure in a gas stream.
Mechanical ventilation to the outside atmosphere is required.
Allows any escape of gas to be smelled or otherwise detected by passers by reduces condensation the total effective ventilation area free area shall not be less than 2 of the internal floor area of the housing or its notional equivalent and should be equally distributed and disposed at high and low levels around the outside walls.
N interior gas piping is complete and connected to the meter bracket.
Meter room in accordance with as nzs 60079 10 1 2009 the metering room shall.
The gas safety installation and use regulations 1998 part c regulation 13 1 where a meter is housed in a meter box or meter compound attached to or built into the external face of the outside wall of any premises the meter box or meter compound shall be so constructed and installed that any gas escaping within the box or compound cannot enter the.
3 0 gas meter and regulator locations continued.
Before requesting a new meter installation please be sure the following items have been completed.
Natural gas meter requesting a new natural gas meter thank you for choosing national grid.
The meter guys may be referring to.
Maintain a minimum of 3m between any opening from the gas meter room and any gas appliance boiler.
The location of the gas meter room shall be on.
Maintain a minimum of 5m between any opening from the gas meter room and a flammable storage area filling point or pressure vessel.
A duct having a cross section area of at least 50 square inches 32 522 mm 2 of free area.
The requirements of this standard must be met when a customer houseline is added to an existing gas meter room or gas meter set within a building.
Meter box a purpose made glass reinforced polyester moulding to house domestic and small non domestic meters.
An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2.
Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed.
Gas meter room s must be designed to prevent entrapment of gas.
This states that bin rooms should be accessible from the exterior of a building or by way of a protected lobby provided with not less than 0 2 m2 of permanent ventilation.
Gas meter room requirements as per these guidelines and multinet technical standards will be discussed and agreed upon notably regarding civil structural hvac lighting signage service route meter room size venting locations door requirements and location.