Gas meter room requirements as per these guidelines and multinet technical standards will be discussed and agreed upon notably regarding civil structural hvac lighting signage service route meter room size venting locations door requirements and location.
Gas meter room vent.
Allows any escape of gas to be smelled or otherwise detected by passers by.
Additional gas meter may be installed in such room or space provided.
Table illustrations of the required space between a direct or side wall vent for a gas fired heating appliance and building windows doors corners gas meter air intakes sidewalks balconies.
The gas safety installation and use regulations 1998 part c regulation 13 1 where a meter is housed in a meter box or meter compound attached to or built into the external face of the outside wall of any premises the meter box or meter compound shall be so constructed and installed that any gas escaping within the box or compound cannot enter the.
An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2.
Vent meter room location requirements.
An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2.
The natural gas regulator is a critical component of the meter set and needs to be vented and should comply with local and federal venting requirements may vary from.
A duct having a cross section area of at least 50 square inches 32 522 mm 2 of free area.
Gas service line trench features are also described.
Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed.
The purpose of ventilation in a meter installation housing is to.
The location of the gas meter room shall be on.
Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed.
C be protected from damage caused by submergence in areas where.
The meter guys may be referring to.
This article provides a detailed table of example clearance distance specifications for natural gas meter installations giving the distances to various building features such as windows doors electrical components vents air conditioners and outside hose bibs.
This gas meter room is also located at grade level with a door that.
Ensure that minor gas leakage does not cause the atmosphere within the housing to become unsafe.
Gas meter clearance distances.
Be located at a place where gas from the vent can escape freely into the atmosphere and away from any opening into the building a minimum of 18 inches.
A small price to pay in an emergency vent line tips.
A gas meter room that is located adjacent to an outside building wall inside the customer s building and constructed with walls ceiling and floor that are vapor tight to prevent the migration of gas to the building s interior.